X-CABINET
Intelligent Storage & Organization System

X-Cabinet
Robotic cabinet. Inventory and access control.
Description
X-Cabinet is a vertical format robotic assistant that integrates into the office architecture.
X-Cabinet provides automatic delivery and return of dental instruments with average delivery time of 10 seconds and return time of 11 seconds per position, with bulk loading/unloading capability of up to 20 positions in 3–4 minutes.
Assistant Functions
Preparation of sets for planned procedures.
Material delivery in the correct sequence, synchronized with treatment.
Real-time inventory and consumption reports.
Identification and Protection
Voice ID authorization: cabinet access only for authorized doctors and administrators.
Auto-lock for expensive medications: implants, anesthetics and premium materials — in protected modules.
Operations log: logs each user, each dispensed material and operation time.
Anti-theft and misuse protection: upon unauthorized access attempt — blocking and notification of responsible person.
Technical Parameters
Dimensions: dynamic (by client architecture)
- • 105 × 50 × 230 cm
- • 75 × 70 × 230 cm
- • 220 × 45 × 200 cm
Total Volume (V)
1.72 m³ ★
Useful Surface (S)
3.22 m²
Delivery Platform
~60 × 50 cm
Performance Specifications
| Parameter | Min. | Avg. | Max. |
|---|---|---|---|
| Instrument delivery | 6 s | 8–10 s | 16 s |
| Instrument return | 7–8 s | 10–12 s | 18–20 s |
| Bulk load/unload 20 positions | 2.5 min | 3–4 min | 5 min |
| X/Y axes linear speed | 0.3 m/s | 0.4 m/s | 0.5 m/s |
| Z axis speed | 0.2 m/s | 0.25 m/s | 0.3 m/s |
| Cycle time inside cabinet | 5 s | 7–9 s | 12–14 s |
Instrument Handling
Basic Process
The cabinet receives sterile instruments from the sterilization area and automatically organizes them in internal compartments, while sending used ones to the "dirty" block for external sterilization.
Option: Built-in Autoclave
Built-in autoclave in one of the X‑Cabinet modules with automatic loading of dirty instruments and their subsequent organization on shelves after sterilization.
Sterilization of instruments and surfaces is performed by the clinic according to its own protocols.
Equipment installation complies with local and federal law requirements.